Prosense Pc3-6824 | Nitrogen Dioxide | Gas Detectors (explosion-proof) | Gasdetectorseu
Gas Leak and Flame Detectors, Analyzers and Alarm Controllers

PROSENSE   PC3-6824

PROSENSE PC3-6824
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

PC3-6824   
739,20

Relays

   3 Weeks  ]
Epoxy painted aluminum housing

PC3 has a certain higher price-performance ratio considering its substitutes in the market.

Well-Suited Solution for Light Indusrty

PC3 is specially designed for the light industry as a Category 3 device.

Accurate Readings

Electrochemical, and Catalytic sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog is provided onboard to operate properly without any additional setup. Additionally, it can be integrated into other systems with Modbus RS485 RTU and relay module.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL, ppm, VOL levels. The fault relay output properly indicates fault status.

Robust and Reliable Housing

Epoxy painted aluminum housing and IP65 protection class allow to use in harsh environmental conditions.

Universal Outputs

4-20mA Analog, Modbus RS485 RTU, and relay outputs are simple to operate efficiently and they are universally usable in any control panel.

Applications
  • Process Industry
  • Chemical Industry
  • Food and Medicine Facilities
  • Gas Distribution Stations
  • Laboratories
Optional Modules

P-3R+: 2 Alarms and 1 Fault (NO/NC adjustable) relay output card.

Specifications PC3-XY24
Sensing Element Electrochemical
Output Signal 4-20mA Analog
Modbus RS485 RTU
Sensor Warm-Up Time <30*sec
Accuracy %±1
Operating Temperature ‐20°C ~ +50°C
Humidity 5 ~ 95%RH Non-Condensing
Input Voltage Min 10VDC - Max 32VDC - Nominal 24VDC
Power Consumption Max. 2W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 1x 1/2"NPT
Ingress Protection IP65
Enclosure Epoxy Painted Die-Cast Aluminum
Sensor Head Nickel‐Plated Brass SH20
Dimensions 230x120x100mm
Weight 1100gr
Hazardous Class Zone 2 ‐ Category 3
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



9,24 € 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



13,86 € 
SP-PC3-TB02
(7038)

PROSENSE  SP-PC3-TB02

Prosense PC3 Transmitter/Main Board for PC3 series gas detectors



151,80 € 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

151,80 € 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



379,50 € 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

693,00 € 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

808,50 € 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

1.617,00 € 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

2.079,00 € 
> NITROGEN DIOXIDE :    5 Items found.
PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



385,00 € 
PPS-RNO2
(6812)

PROSENSE  PPS-RNO2

Prosense PPS-RNO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



434,50 € 
P-6834
(6784)

PROSENSE  P-6834

Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

808,50 € 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

970,20 € 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

1.108,80 € 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.