Gasdetectorseu.com: Gas Detectors (explosion-proof) - All
Prosense Gas Detectors, ESP Safety Flame Detectors, Felix Produce Monitors, Ex & UL Certified
Gas Leak and Flame Detectors, Analyzers and Alarm Controllers
Gas Leak and Flame Detectors, Analyzers and Alarm Controllers
GAS DETECTORS (EXPLOSION-PROOF) > all :    111 Items found.
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

207,90 € 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic Bead and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

277,20 € 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

277,20 € 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

392,70 € 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

392,70 € 
PC3-6524
(6806)

PROSENSE  PC3-6524

Prosense PC3-6524 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

415,80 € 
PC3-4424
(6802)

PROSENSE  PC3-4424

Prosense PC3-4424 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

415,80 € 
PC3-6424
(6805)

PROSENSE  PC3-6424

Prosense PC3-6424 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with range 0-100 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

462,00 € 
P-6534
(6781)

PROSENSE  P-6534

Prosense P-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

485,10 € 
P-3634
(6776)

PROSENSE  P-3634

Prosense P-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

485,10 € 
P-4434
(6777)

PROSENSE  P-4434

Prosense P-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm to 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

485,10 € 
P-6035
(6779)

PROSENSE  P-6035

Prosense P-6035 Gas Detector with Catalytic Bead sensor for Acetylene (C2H2) with range 0-100%LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

485,10 € 
P-6434
(6775)

PROSENSE  P-6434

Prosense P-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

531,30 € 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

554,40 € 
PQN-5535-1/2
(6950)

PROSENSE  PQN-5535-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

554,40 € 
PQN-6035-1/2
(6951)

PROSENSE  PQN-6035-1/2

Prosense PQN-6035 Gas Detector with Catalytic Bead sensor for Acetylene (C2H2) with range 0-100%LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

646,80 € 
PQN-4434-1/2
(6949)

PROSENSE  PQN-4434-1/2

Prosense PQN-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

646,80 € 
PQN-3634-1/2
(6948)

PROSENSE  PQN-3634-1/2

Prosense PQN-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

646,80 € 
PQN-6534-1/2
(6954)

PROSENSE  PQN-6534-1/2

Prosense PQN-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

646,80 € 
P-7231
(6787)

PROSENSE  P-7231

Prosense P-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

669,90 € 
Page: *1 | 2 | 3 | 4 | 5 | 6 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.