Prosense P-3012pek | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorseu
Gas Leak and Flame Detectors, Analyzers and Alarm Controllers

PROSENSE   P-3012PEK

PROSENSE P-3012PEK
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense P-XY12PEK Gas Detector with Catalytic and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

P-3012PEK
269,50

Gas
Relays

   3 Weeks  ]


Combination of Gas and Shock Impact Detectors

PE-KAYO Series specially designed for the Oil&Gas stations as it has multiple functions. The detector has a special accelerometer chip inside to monitor physical bumps happening on the location where the device installed along with gas measurement functions. It can generate an alarm to cut the gas and oil flow if car or truck hits the detector or the mounted shaft.

Trustworthy Certification

PROSENSE "PE-KAYO" Series fixed gas detectors are certified with ATEX/IECEx.

Ex-proof Safety

The continuous measurement of explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Cost-Effective Solutions

“PE-KAYO” Series offers cost-effective solutions in Oil&Gas industry.

Robust and Durable

“PE-KAYO” performs perfectly under the harsh environmental conditions with the IP65 protection class.

Accurate Readings

Long-lasting Catalytic sensors undoubtedly provide an accurate and sensitive gas detection.

Universal 4-20mA Analog Signal Output

4-20mA Analog, Modbus RS485 RTU, Relay and Voltage outputs are simple to operate efficiently and universally.

Quick Response Time

Catalytic sensor in PE-KAYO offers quick response time for detecting combustible gases.

Durable Sensor

PE-KAYO Series uses a special Catalyic sensor which has a long life-time.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL levels. The fault relay output properly indicates fault status.

Applications
  • LNG/LPG
  • Oil&Gas
  • Gas Distribution Stations
Optional Modules

P-3R+: 2 Alarms and 1 Fault (NO/NC adjustable) relay output The fault relay output properly indicates fault status. card.

Specifications P-XY12PEK
Sensing Element Catalytic
Motion Sensor 3 axis (3D accelerometer)
Output Signal 4-20mA Analog
Modbus RS485 RTU
Sensor Warm-Up Time 60sec
Response Time(T90) <15sec
Accuracy %±1
Operating Temperature -40°C ~ +70°C
Humidity 5 ~ 95%RH Non-Condensing
Input Min 10VDC - Max 28VDC - Nominal 24VDC
Power Consumption Max. 4W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 1/2''NPT
IP Rating IP65
Junction Box Epoxy Painted Die-Cast Aluminum
Sensor Head Nickel‐Plated Brass
Dimensions/Weight 172,5x118,15x88mm / 1150gr
ATEX Marking II 2G Ex db IIC T5/T4 Gb
Hazardous Class Zone 1 or Zone 2
Certificates IMQ 19 ATEX 045 X
IECEx IMQ 18.0009X
Standards IEC EN 60079-0
IECEx IMQ 18.0009X
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

> ACCESSORIES - RELATED - CONSUMABLES :    11 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



3,09 € 
P-NYY12
(6976)

PROSENSE  P-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



10,78 € 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

223,30 € 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



303,60 € 
P-HH
(7056)

PROSENSE  P-HH

Prosense Handheld Terminal for maintenance, diagnostics, alarm setting, configuration, test and calibration of Prosense PQN, PQD, P and PC3 series gas detectors, uses RS-485 Modbus to connect to the detectors.



337,33 € 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

404,80 € 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

546,70 € 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

677,60 € 
S-DP32
(6985)

PROSENSE  S-DP32

Prosense S-DP32 Gas Detector Controller, Alarm Panel for Up to 32 addressable gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL). Fault, Alarm1, Alarm2 and AUX Relays. RS485 interface and status LEDs for each channel. LCD Display. ABS Housing, IP66.

Configure

847,00 € 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

1.540,00 € 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

2.002,00 € 
> LEL CATALYTIC BEAD :    7 Items found.
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

177,10 € 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

373,45 € 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

373,45 € 
PQN-5535-1/2
(6950)

PROSENSE  PQN-5535-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

539,00 € 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

539,00 € 
PQD-5535-1/2
(6736)

PROSENSE  PQD-5535-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

654,50 € 
PQD-3035-1/2
(6718)

PROSENSE  PQD-3035-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

654,50 € 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.